home *** CD-ROM | disk | FTP | other *** search
- IMPORTANT GVP Series II SCSI Controller INFORMATION
-
-
-
- SIMMS: The SIMMs must be inserted in a specific order. They go in from
- the innermost (CN10) to the outermost (CN17) sockets. The outermost
- socket would be the one closest to the card's edge.
-
-
-
- SIMM JUMPERS: You must add memory in 2-meg increments
-
-
-
- Memory SIMM LOcations J5 J6 J7 J8 J9
-
- 0 NONE off off on off on
-
- 2 CB10-CN11 off on off off on
-
- 4 CN10-CN13 on off off off on
-
- 6 CN10-CN15 off off on on off
-
- 8 CN10-CN17 off on off on off
-
-
-
- SCSI TERMINATION: For the first SCSI internal drive:
-
-
-
- 1. Remove all terminating resistor packs from the internal hard drive.
-
- 2. Set its ID to zero (no jumpers on SCSI jumper pins).
-
-
-
- If there are more than 1 SCSI device, the last ID drive should be
- terminated (if internal and external, only the last ID EXTERNAL drive
- needs to be terminated).
-
-
-
- MISC JUMPERS:
-
-
-
- J4 is the autoboot jumper
-
- J10-J12 are SCSI-ID jumpers (all off for ID=0,all on for ID=7)
-
-
-
- CN1 is the LED hard disk light connector.
-
-